#Profibus_DP ; PrmText = 1 Text(0) = "disabled" Text(1) = "enabled" EndPrmText PrmText = 2 Text(0) = "4 x Pt100" Text(1) = "4 x Pt1000" Text(2) = "4 x Potentiometer 3-wire" Text(3) = "4 x Potentiometer 2-wire" Text(4) = "ch1&2 Pt100 ch3&4 Pot. 3-wire" Text(5) = "ch1&2 Pt100 ch3&4 Pot. 2-wire" Text(6) = "ch1&2 Pt1000 ch3&4 Pot. 3-wire" Text(7) = "ch1&2 Pt1000 ch3&4 Pot. 2-wire" Text(8) = "send 0000hex on all channels" Text(9) = "send 7FFFhex on all channels" EndPrmText PrmText = 3 Text(0) = "50Hz" Text(1) = "60Hz" EndPrmText ; ExtUserPrmData = 1 "diagnosis ch.1" Bit(0) 1 0-1; Default = 1, Min = 0, Max = 1 Prm_Text_Ref = 1 EndExtUserPrmData ExtUserPrmData = 2 "diagnosis ch.2" Bit(1) 1 0-1; Default = 1, Min = 0, Max = 1 Prm_Text_Ref = 1 EndExtUserPrmData ExtUserPrmData = 3 "diagnosis ch.3" Bit(2) 1 0-1; Default = 1, Min = 0, Max = 1 Prm_Text_Ref = 1 EndExtUserPrmData ExtUserPrmData = 4 "diagnosis ch.4" Bit(3) 1 0-1; Default = 1, Min = 0, Max = 1 Prm_Text_Ref = 1 EndExtUserPrmData ExtUserPrmData = 5 "Set Input Channels" BitArea(0-3) 9 0-9 Prm_Text_Ref=2 EndExtUserPrmData ExtUserPrmData = 6 "Input filter for PT100(0)" Bit(0) 0 0-1; Default = 0, Min = 0, Max = 1 Prm_Text_Ref = 3 EndExtUserPrmData ; GSD_Revision = 1 ; Vendor_Name = "BARTEC GmbH" Model_Name = "4 x RTD in" ORDERNUMBER = "07-7331-2307" Revision = "11.07.2000" Ident_Number = 0x2307 Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "HR1" Software_Release = "SR1" ; 9.6_supp = 1 19.2_supp = 1 45.45_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 ; MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_45.45 = 250 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 ; Redundancy = 0 Repeater_Ctrl_Sig = 0 24V_Pins = 0 Implementation_Type = "SPC3" ; Freeze_Mode_supp = 1 Sync_Mode_supp = 0 Auto_Baud_supp = 1 Set_Slave_Add_supp = 0 Min_Slave_Intervall = 1 ; Max_User_Prm_Data_Len = 6 Ext_User_Prm_Data_Const(0) = 0x00, 0x00, 0x00, 0xff, 0x09, 0x00 Ext_User_Prm_Data_Ref(3) = 1 Ext_User_Prm_Data_Ref(3) = 2 Ext_User_Prm_Data_Ref(3) = 3 Ext_User_Prm_Data_Ref(3) = 4 Ext_User_Prm_Data_Ref(4) = 5 Ext_User_Prm_Data_Ref(5) = 6 ; Fail_Safe = 0 Slave_Family = 3 Max_Diag_Data_Len = 8 ; Unit_Diag_Bit(0) = "ch.1 short circuit / wire break" Unit_Diag_Bit(1) = "ch.2 short circuit / wire break" Unit_Diag_Bit(2) = "ch.3 short circuit / wire break" Unit_Diag_Bit(3) = "ch.4 short circuit / wire break" Unit_Diag_Bit(4) = "ch.1 internal malfunction" Unit_Diag_Bit(5) = "ch.2 internal malfunction" Unit_Diag_Bit(6) = "ch.3 internal malfunction" Unit_Diag_Bit(7) = "ch.4 internal malfunction" ; ; Module="module 1" 0x00,0x53 EndModule ;